17.08.2022, News

METEC Field-Test Campaign

We organized a field-test campaign at the METEC (Methane Emissions Technology Evaluation Center) with our Nubo Sphere methane emissions monitoring solution. Want to learn more about the results?

No alternate text provided

Our report shows the findings and results of the field-testing campaign at Colorado State University’s Methane Emissions Technology Evaluation Center (METEC) to simulate real-world environmental conditions under a controlled setting.

 

Here you can find a short summary of our field test results with 8 Nubo Sphere sensor nodes. To get access to the full in-depth report, please get in contact with us.

 

 

Test Facility 
Size of overall site90 m x 50 m 
- 
Tests 
Experiment period23.05. - 03.06.2022 (9 days)
Total number of emissions27
Total methane emissions249.7 kg
Emission rate range0.6 - 7.7 kg/h
Average duration of an emission2.4 hours
- 
Results (8 Sensor Nodes) 
Detected Emissions27/27 = 100%
Average Time to Detection31 minutes
Average Time to Confirmed Detection2.5 hours
Average Emission Location Accuracy4 m
Average Emission Rate Accuracy-34%
Quantified Emission Accuracy-24%
 *R2 = 0.91

 

 

 

 

 

 

 

 

 

 


 

 

 

Latest updates